Select Page

Developed for integrators, designed to be robust so they are reliable in the field and easy to set up

This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for the KNX standard datapoint types (DPTs) and its flexible Modbus register map, it guarantees seamless integration with any KNX device or system.

Configured by ETS software. The officially certified ETS database provides all the necessary parameters to configure both sides of the integration, with up to 100 Modbus registers to integrate into KNX.

Integrate any Modbus RTU slave device with any KNX device or system using ETS. The aim of this integration is to make accessible any Modbus registers data and resources from a KNX system as if it was part of the own KNX system and vice-versa.

Modbus Protocol Translators

Bring connectivity to your Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI, or M-BUS devices to Modbus systems and extend your building management system capabilities.

Intesis Modbus can act as a Modbus RTU device, Modbus TCP device, or both.

On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).

On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.

  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
  • Scaled licenses per number of datapoints help to find the right gateway version for your project.
  • Modbus advanced functionalities to improve internal and external protocol communications.
  • Modbus template repository with most common Modbus devices and template generator to create your own template devices.

Modbus TCP & RTU

All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.

Most I/O Modbus functions supported

Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).

Multiple data formats

Configure the data length (1, 16, 32, 48, or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little-endian).

Polling groups

Improve Modbus communications grouping register requests per device, asking multiple registers in a single request.

KNX Protocol Translators

Provide BACnet, DALI, M-Bus, or Modbus communication to your KNX installations. Intesis KNX solutions offer a perfect integration in any KNX project thanks to the availability of multiple standard DPT (Data Point Types) and our expertise in KNX solutions.

Intesis KNX connects directly to the KNX TP-1 bus and behaves like any other device in the KNX system, with the same configuration and operational characteristics as other KNX devices.

  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
  • Scaled licenses per number of datapoints help to find the right gateway version for your project.

Standard KNX Datapoint Types

It ensures interoperability and data quality between different manufacturers’ devices.

Extended group addresses

In big projects actívate extended group addresses and use up to 32 main group addresses in a 3-Level configuration.

Sending and listening addresses

Every point can be addressed not only using its main group address but also using the other defined listening addresses for the point.

Ri flag (Read on initialisation flag)

In order to get updated data as soon as possible, KNX gateways could requests updated data to the bus after initialisation, instead of waiting for changes.

Product Information

  • KNX Certified.
  • Support for Modbus RTU only (RS485).
  • Support for KNX TP.
  • Supports KNX standard data points (DPTs) that guarantees seamless integration with any KNX device or system.
  • Operations for each signal to adapt Modbus register to demanding KNX installations: E.g. multiplication, division, and equal to.
  • Reduced dimensions, compact housing.
  • Up to 100 Communication Objects.
  • Up to 255 Modbus Devices.
  • Easy integration & configuration with standard ETS database.
ORDER CODES: 

INKNXMBM1000100  Modbus RTU Master to KNX TP Gateway – 100 points
  • Intesis Gateway.
  • Installation Manual.
  • Warranty: 36 months.

Book your product

We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.

Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.

CONTACT US

Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970

SOCIAL MEDIA